Erratum in: “Real-Time Risk Score for Glaucoma Mass Screening by Spectral Domain Optical Coherence Tomography: Development and Validation” by Kota Fukai, Ryo Terauchi, Takahiko Noro, Shumpei Ogawa, Tomoyuki Watanabe, Toru Nakagawa, Toru Honda, Yuya Watanabe, Yuko Furuya, Takeshi Hayashi, Masayuki Tatemichi, and Tadashi Nakano (
Transl Vis Sci Technol. 2022;11(8):8),
https://doi.org/10.1167/tvst.11.8.8.
When the article was originally published, in Table 1, the values of SD-OCT measured thickness in cases and in controls were 82.0 ± 27.2 and 123.4 ± 17.8 in mRNFL (10 × 10 grids); 69.9 ± 11.9 and 79.5 ± 9.2 in mGCIPL (10 × 10 grids); and 151.9 ± 31.9 and 202.9 ± 21.2 in mGCC (10 × 10 grids), respectively. However, after reanalysis, each value was found to be incorrect due to simple miscalculations. The correct values are 32.8 ± 5.2 and 37.6 ± 4.3 in mRNFL (10 × 10 grids); 54.7 ± 7.1 and 65.4 ± 5.2 in mGCIPL (10 × 10 grids); and 87.4 ± 10.4 and 103.0 ± 8.0 in mGCC (10 × 10 grids), respectively. The values, shown in bold in the tables below, have been changed in the article online. The corrections to these values do not affect any of the fundamental results or interpretations of the paper.